Take off the wall face first
Begin with a wall schedule rather than a floor-area estimate. Record length, height, thickness and every opening for each wall type. Use one measurement system throughout. An opening measured in feet must be converted before it is deducted from a wall measured in metres.
For a rectangular wall, gross face area is length × height. Deduct the actual opening areas to obtain net face area. Check whether the drawing dimensions refer to the structural opening, the finished opening or a nominal door size. These can differ, and the take-off should use the coordinated wall geometry.
Choose the block length and width separately
The approved CELBLOC range has 450 and 600 mm lengths, both 200 mm high, in widths of 100, 150 and 200 mm. The face area is length × height. Changing width changes wall thickness and unit volume, but it does not change this theoretical face coverage. [source]
| Unit length | Face area | Units per m² |
|---|---|---|
| 450 mm | 0.450 × 0.200 = 0.090 m² | 11.111… |
| 600 mm | 0.600 × 0.200 = 0.120 m² | 8.333… |
Use the unrounded face area in the calculation. The displayed recurring units-per-square-metre values are explanatory, not factors to round early.
Work through a complete example
Consider a 6 m long × 3 m high wall with openings totalling 3 m². Gross area is 18 m² and net area is 15 m². Choose an illustrative 5% cutting and wastage allowance.
- 450 mm length: 15 ÷ 0.09 × 1.05 = 175 blocks.
- 600 mm length: 15 ÷ 0.12 × 1.05 = 131.25, rounded up to 132 blocks.
The calculation is the same for all three widths; the width must still be specified in the order. Round only the final quantity for the chosen procurement grouping. If you round every short wall separately before combining it, the total can exceed a combined calculation.
The example is a preliminary geometric estimate, not a purchase instruction. Five per cent is an assumption that should be reviewed against wall complexity, cutting practice, handling and the intended reuse of offcuts.
Understand what this method excludes
The face-area method excludes mortar joints. An exact coursing take-off needs actual unit dimensions, joint thickness, bond, end cuts and the arrangement around openings. It also needs the approved layout for the selected length. The 450 mm bond deserves particular attention because its half-length differs from the archived overlap guidance.
Keep mortar, reinforcement or restraints, lintel arrangements, finishes, delivery and unloading separate from the block count. A block allowance does not automatically cover those items. Avoid using wall volume to order units unless you have checked that the intended thickness and opening deductions are consistent.
Turn the estimate into an order schedule
- Separate walls by selected length, width and required grade.
- Confirm net areas against the current drawing revision.
- Review bond, cuts, handling and the allowance with the site team.
- Check availability, tolerances and delivery sequence with Materials.
- Issue the final take-off with its assumptions and exclusions.
Our block calculator follows this face-area method and lets you review an estimate before carrying it into an enquiry. It is useful for a first conversation; the coordinated wall schedule remains the basis for the final order.